FUNMAT PRO 310 NEO Service Guide
¶
Chapter 1 - Error and diagnosis
¶
01. E301 - L-Nozzle temperature is too high
¶
02. E302 - R-Nozzle temperature is too high
¶
03. E303 - Build-plate temperature is too high
¶
04. E304 - Chamber temperature is too high
¶
05. E305 - Left nozzle temp is too low
¶
06. E306 - Right nozzle temp is too low
¶
07. E307 - Build-plate temp is too low
¶
08. E308 - Printing Chamber temp is too low
¶
09. E312 - Left nozzle heat speed is too slow
¶
10. E313 - Right nozzle heat speed is too slow
¶
11. E314 - Buildplate T heating timeout
¶
12. E315 - Chamber T heating timeout
¶
13. E217 - Left nozzle is out of material
¶
14. E218 - Right nozzle is out of material
¶
15. E221 - Chamber front door is open
¶
16. E222 - Chamber top door is open
¶
17. E332 - X limit switch is triggered
¶
18. E333 - Y limit switch is triggered
¶
19. E334 - Z limit switch is triggered
¶
20. E235 - Left leveling sensor is triggered
¶
21. E366 - XYZMotor driver alarm
¶
22. E368 - E Motor driver error
¶
23. E369 - E Motor driver error
¶
24. E397 - Nozzle temperature update error
¶
25. E398 - Incorrect G-code motion data
¶
Chapter 2 - Common Issues & Tips
¶
01. Nozzle Clogging
¶
02. Build-plate adhesion issue
¶
03. Layer Separation
¶
04. Stringing Issue
¶
05. Under Extrusion
¶
06 . Layer Shift
¶
07. Random Protrusion on Surface
¶
08. Prime Tower and Collapse Issue
¶
09. Z-Seam Issue (Z-Weld Point Alignment)
¶
10. Purpose of Nozzle Cooling Fan
¶
11. Purpose of Chamber Heating
¶
12. Support and Overhand
¶
Chapter 3 - Parts disassembling
¶
Section 1. Surrounding Components
¶
1.1 Front Door Interlock & Sensor
¶
1.2 Top Door Interlock & Sensor
¶
1.3 Main Power Switch & the Fuse
¶
1.4 24VDC Power Supply
¶
1.5 Main Board
¶
1.6 Filament Sensor, Tube Fitting (Bridge), Black Top Surrounding Cover
¶
1.7 Touch Screen, USB Port & Power on Button
¶
1.8 LED Light
¶
1.9 Step Motor Driver
¶
Section 2. Printing Chamber
¶
2.1 HEPA Filter
¶
2.2 Chamber Heating Fans
¶
2.3 Chamber Heater
¶
2.4 Power Relay for Chamber Heater (K2)
¶
2.5 Print Chamber Thermal Sensor (Temperature sensor)
¶
2.6 Build-plate Heater
¶
2.7 Bellows - X&Y axis
¶
2.8 handle of build-plate sheet
¶
2.9 Auto-leveling Sensor
¶
Section 3. Extruder Assembly
¶
3.1 Heating Cartridge(heater) and Temperature Sensor of Hot End & Nozzle
¶
3.2 Interconnection Board on Extruder Assembly
¶
3.3 Feed Motor
¶
3.4 The Idle gear (Feeding Filament)
¶
3.5 Base of Extruder, Nozzle Cooling Fan, Throat Cooling Fan, Interconnection PCB of the Base
¶
Section 4. Motion Structure
¶
4.1 Z axis driving motor
¶
4.2 X motor
¶
4.3 Y motor
¶
4.4 Limit sensor of X, Y, Z axis
¶
Section 5. Firmware & Software Upgrade
¶
5.1 Software Upgrade
¶
5.2 Firmware Upgrade
¶
Chapter 4 - Operations
¶
1. Export Log Files
¶
2. Lan Connection (Wifi & Wired ethernet)
¶
3. Remote Printing & Monitoring