FUNMAT PRO 410 Service Guide
¶
Chapter 1 - Error and diagnosis
¶
01.
E301 - L-Nozzle temperature is too high
¶
02.
E302 - R-Nozzle temperature is too high
¶
03.
E303 - Build-plate temperature is too high
¶
04.
E304 - Chamber temperature is too high
¶
05.
E306 - Left nozzle temperature is too low
¶
06.
E105-Temperature of filament chamber is too high
¶
07.
E307 - Right nozzle temperature is too low
¶
08.
E308 - Build-plate temperature is too low
¶
09.
E309 - Chamber temperature is too low
¶
10.
E310 - Left nozzle temperature does not change during heating
¶
11.
E311 - Right nozzle temperature does not change during heating
¶
12.
E312 - L-nozzle heating speed is too low
¶
13.
E313 - R-nozzle heating speed is too low
¶
14.
E416-The device is powered off or the voltage is unstable during printing
¶
15.
E217 - L-failment is out of material
¶
16.
E218 - R-filament is out of materail
¶
17.
E219- L-nozzle extrusion is abnormal
¶
18.
E220- R-nozzle extrusion is abnormal
¶
19.
E221 - The front door of the chamber is not closed
¶
20.
E222 - The top door of the chamber is not closed
¶
21.
E123 - The door of filament chamber is not closed
¶
22.
E224 - L-Extruder limit sensor is abnormal
¶
23.
E225 - R-Extruder limit sensor is abnormal
¶
24.
E129 - cooling liquid temperature is high
¶
25.
E130 - L-filament weight is probably not enough
¶
26.
E131 - R-filament weight is probably not enough
¶
27.
E332 - X limit sensor is triggered
¶
28.
E333 - Y limit sensor is triggered
¶
29.
E334 - Z limit sensor is triggered
¶
30.
E235 - L-nozzle leveling sensor is triggered
¶
31.
E237-Cooling liquid temperature is high
¶
32.
E238-Cooling liquid temperature is low
¶
33.
E252-liquid tank temperature sensor is broken
¶
34.
E253-liquid tank temperature sensor is short circuit
¶
35.
E254-liquid tank temperature sensor is low
¶
36.
E256-liquid flow is low
¶
37.
E257-cooling liquid is abnormal
¶
38.
E370/371-Serial COM error
¶
39.
E171 - Serial COM error
¶
Chapter 2 - Common Issues & Tips
¶
01. Nozzle Clogging
¶
02. Build-plate adhesion issue
¶
03. Layer Separation
¶
04. Stringing Issue
¶
05. Under Extrusion
¶
06. Layer Shift
¶
07. Random Protrusion on Surface
¶
08. Prime Tower and Collapse Issue
¶
09. Z-Seam Issue (Z-Weld Point Alignment)
¶
10. Purpose of Nozzle Cooling Fan
¶
11. Purpose of Chamber Heating
¶
12. Support and Overhand
¶
Chapter 3 - Parts disassembling
¶
Section 1. Surrounding Components
¶
1.1
Top Door Air Spring
¶
1.2
Touch Screen, USB Port & Power-On Button
¶
1.3
Top Door Interlock & Sensor
¶
1.4
Motor Driver
¶
1.5
Main Board & UPS Board
¶
1.6
24VDC Power Supply & Capacity
¶
1.7
Touch Screen, USB Port & Power on Button
¶
Section 2. Extruder Assembly
¶
2.1
Extruder Assembly
¶
2.2
Nozzle set, Hot end, Heating, Cartridge, T Sensor
¶
2.3
Feed Motor
¶
2.4
Nozzle switch motor & right nozzle lifter
¶
2.5
Encoder, Nozzle switch sensor, Auto-leveling sensor
¶
Section 3. Chiller
¶
3.1
Chiller
¶
3.2
Coolant Temperature Sensor
¶
3.3
settings of Chiller
¶
Section 4. Printing Chamber
¶
4.1
Chamber Heater
¶
4.2
Heating fans(blower)
¶
4.3
Temperature sensor of printing chamber
¶
4.4
build-plate Heater
¶
4.5
Nozzle Cleaning station(scraper & brush)
¶
Section 5. Filament Chamber
¶
5.1
Filament I/O Board
¶
5.2
Filament feed motor (filament chamber)
¶
5.3
Heaters&fans in filament chamber ,fuse for the Heaters in main board
¶
5.4
Temperature sensor in filament chamber
¶
5.5
Filament Absence Sensor
¶
Section 5.
Motion Structure
¶
6.1
Driving motor-Z Axis ,Z limit sensor &Activation flag
¶
6.2
Driving motor-Y Axis,Y limit sensor
¶
6.3
Rails-Y Axis
¶
6.4
Y Axis-Limit sensor
¶
6.5
X motor
¶
6.6
X limit sensor
¶
6.7
Rails-X Axis
¶
Chapter 4 - Operations
¶
1.
Upgrade firmware of lower computer (Main Board)
¶
2.
Upgrade software of upper computer